Unix Study--Solaris 10添加新网卡
发表于:2025-01-23 作者:千家信息网编辑
千家信息网最后更新 2025年01月23日,Unix Study--Solaris 10添加新网卡在Solaris 10上构建Oracle RAC ,在系统上添加了新的网卡,如何识别和配置相关的参数呢?本案例结合实际应用讲述如何配置第二块网卡1
千家信息网最后更新 2025年01月23日Unix Study--Solaris 10添加新网卡
Unix Study--Solaris 10添加新网卡
在Solaris 10上构建Oracle RAC ,在系统上添加了新的网卡,如何识别和配置相关的参数呢?本案例结合实际应用讲述如何配置第二块网卡
1、查看网卡名称
[root@node1:/]# ifconfig -alo0: flags=2001000849 mtu 8232 index 1 inet 127.0.0.1 netmask ff000000 e1000g0: flags=1000843 mtu 1500 index 2 inet 192.168.8.11 netmask ffffff00 broadcast 192.168.8.255 ether 8:0:27:28:b1:8c
2、查看新网卡名称
[root@node1:/]# more /etc/path_to_inst
## Caution! This file contains critical kernel state#"/iscsi" 0 "iscsi""/pseudo" 0 "pseudo""/options" 0 "options""/xsvc" 0 "xsvc""/objmgr" 0 "objmgr""/scsi_vhci" 0 "scsi_vhci""/isa" 0 "isa""/isa/i8042@1,60" 0 "i8042""/isa/i8042@1,60/keyboard@0" 0 "kb8042""/isa/i8042@1,60/mouse@1" 0 "mouse8042""/isa/lp@1,378" 0 "ecpp""/ramdisk" 0 "ramdisk""/cpus" 0 "cpunex""/cpus/cpu@0" 0 "cpudrv""/pci@0,0" 0 "pci""/pci@0,0/display@2" 0 "vgatext""/pci@0,0/pci106b,3f@6" 0 "ohci""/pci@0,0/pci106b,3f@6/input@1" 0 "hid""/pci@0,0/pci8086,1e@3" 0 "e1000g""/pci@0,0/pci8086,2829@d" 0 "ahci""/pci@0,0/pci8086,2829@d/disk@0,0" 0 "sd""/pci@0,0/pci8086,2829@d/cdrom@1,0" 1 "sd""/pci@0,0/pci8086,2829@d/disk@2,0" 2 "sd""/pci@0,0/pci8086,1e@8" 1 "e1000g""/agpgart" 0 "agpgart"
本机第一块网卡名称"e1000g0",则第二块网卡应为"e1000g1".
2、启用第二块网卡
[root@node1:/]# ifconfig e1000g1 plumb[root@node1:/]# ifconfig -alo0: flags=2001000849mtu 8232 index 1 inet 127.0.0.1 netmask ff000000 e1000g0: flags=1000843 mtu 1500 index 2 inet 192.168.8.11 netmask ffffff00 broadcast 192.168.8.255 ether 8:0:27:28:b1:8c e1000g1: flags=1000842 mtu 1500 index 3 inet 0.0.0.0 netmask 0 ether 8:0:27:6e:16:1
3、添加网卡配置信息
[root@node1:/]# cat /etc/hosts## Internet host table#::1 localhost 127.0.0.1 localhost 192.168.8.11 node1 loghost192.168.8.13 node1-vip10.10.10.11 node1-priv ;;第二块网卡ip[root@node1:/]# cat /etc/hostname.e1000g1node1-priv[root@node1:/]# cat /etc/netmasks ## The netmasks file associates Internet Protocol (IP) address# masks with IP network numbers.# # network-number netmask## The term network-number refers to a number obtained from the Internet Network# Information Center.## Both the network-number and the netmasks are specified in# "decimal dot" notation, e.g:## 128.32.0.0 255.255.255.0#192.168.8.0 255.255.255.010.10.10.0 255.255.255.0 ;;第二块网卡子网掩码[root@node1:/]# cat /etc/inet/ipnodes ## Internet host table#::1 localhost 127.0.0.1 localhost 192.168.8.11 node1 loghost192.168.8.13 node1-vip10.10.10.11 node1-priv[root@node1:/]# sync;sync;reboot ;;重启系统查看网卡信息,新网卡被启用:[root@node1:/]# ifconfig -alo0: flags=2001000849mtu 8232 index 1 inet 127.0.0.1 netmask ff000000 e1000g0: flags=1000843 mtu 1500 index 2 inet 192.168.8.11 netmask ffffff00 broadcast 192.168.8.255 ether 8:0:27:28:b1:8c e1000g1: flags=1000843 mtu 1500 index 3 inet 10.10.10.11 netmask ffffff00 broadcast 10.10.10.255 ether 8:0:27:6e:16:1
@至此,新网卡配置完成!
附注:
Solaris 10识别新硬盘:
添加新硬盘后,没有被识别,解决方法如下:
[root@node1:/]# touch /reconfigure
[root@node1:/]# sync;sync;reboot
[root@node1:/]# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0
/pci@0,0/pci8086,2829@d/disk@0,0
1. c0t2d0
/pci@0,0/pci8086,2829@d/disk@2,0
@硬盘被识别!
网卡
配置
名称
硬盘
信息
系统
参数
实际
方法
至此
附注
e.g
子网
本机
应用
数据库的安全要保护哪些东西
数据库安全各自的含义是什么
生产安全数据库录入
数据库的安全性及管理
数据库安全策略包含哪些
海淀数据库安全审计系统
建立农村房屋安全信息数据库
易用的数据库客户端支持安全管理
连接数据库失败ssl安全错误
数据库的锁怎样保障安全
网络技术对gis产生的影响
网络安全防护防得住是
绿盟湖南网络安全
甲骨文数据库收费标准
易优网络技术有限公司官网
win10有没有自带数据库
专家谈网络安全审查
服务器搭建ghost中转
将span的值存入数据库
pc老头环服务器
秒针嘀嗒网络技术有限公司
店铺数据库设计
临泉职工网络安全
山东安全接入服务器地址
方舟进入不了别人的服务器
太极安全加固服务器
软件开发哪个公司好
北京易拍网络技术有限公司电话
系统和网络安全保障服务
贵州学习软件开发服务商
迅蓝互联网科技
怎么获取服务器的密码
吉林智慧团建软件开发系统
宏基笔记本电脑无法连接服务器
永劫无间其他服务器怎么进
温州温华网络技术有限公司
鼠类病毒数据库
数据可以确保网络安全吗
电脑安装后找不到服务器列表
深圳金极限互联网科技有限