千家信息网

Solaris简单系统巡检,日志查看

发表于:2024-09-22 作者:千家信息网编辑
千家信息网最后更新 2024年09月22日,1、查看message日志;查看是否有errorbash-3.2# more messagesJul 22 18:51:46 sunm4k_2 fmd: [ID 377184 daemon.error
千家信息网最后更新 2024年09月22日Solaris简单系统巡检,日志查看

1、查看message日志;查看是否有error

bash-3.2# more messagesJul 22 18:51:46 sunm4k_2 fmd: [ID 377184 daemon.error] SUNW-MSG-ID: SUN4U-8000-2S, TYPE: Fault, VER: 1, SEVERITY: MajorJul 22 18:51:46 sunm4k_2 EVENT-TIME: 20Jul 22 18:51:46 sunm4k_2 PLATFORM: SUNW,SPARC-Enterprise, CSN: BDF1115195, HOSTNAME: sunm4k_2Jul 22 18:51:46 sunm4k_2 SOURCE: cpumem-diagnosis, REV: 1.7Jul 22 18:51:46 sunm4k_2 EVENT-ID: ecf24522-5df2-ef85-8ead-a0af51b30d08Jul 22 18:51:46 sunm4k_2 DESC: The number of correctable errors associated with this memory module has exceeded acceptable levels.Jul 22 18:51:46 sunm4k_2 AUTO-RESPONSE: Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.Jul 22 18:51:46 sunm4k_2 IMPACT: Total system memory capacity has been reduced.Jul 22 18:51:46 sunm4k_2 REC-ACTION: Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at http://sun.com/msg/SUN4U-8000-2S for the latest service procedures and policies regarding this diagnosis.


2、prtdiag ;注意查看status

bash-3.2# prtdiag -vSystem Configuration:  Oracle Corporation  sun4u SPARC Enterprise M4000 ServerSystem clock frequency: 1012 MHzMemory size: 65536 Megabytes==================================== CPUs ====================================      CPU                 CPU                         Run    L2$    CPU   CPU LSB   Chip                 ID                         MHz     MB    Impl. Mask---   ----  ----------------------------------------  ----   ---    ----- ---- 00     0      0,   1,   2,   3,   4,   5,   6,   7   2530   5.5        7  161 00     1      8,   9,  10,  11,  12,  13,  14,  15   2530   5.5        7  161 00     2     16,  17,  18,  19,  20,  21,  22,  23   2530   5.5        7  161 00     3     24,  25,  26,  27,  28,  29,  30,  31   2530   5.5        7  161============================ Memory Configuration ============================       Memory  Available           Memory     DIMM    # of  Mirror  InterleaveLSB    Group   Size                Status     Size    DIMMs Mode    Factor    ---    ------  ------------------  -------    ------  ----- ------- ---------- 00    A        32768MB            okay       2048MB     16 no       8-way 00    B        32768MB            okay       2048MB     16 no       8-way========================= IO Devices =========================    IO                                                Lane/Frq                                                       LSB Type  LPID   RvID,DvID,VnID       BDF       State Act,  Max   Name                           Model               --- ----- ----   ------------------   --------- ----- ----------- ------------------------------ --------------------    Logical Path    ------------00  PCIe  0      bc, 8532, 10b5       2,  0,  0  okay     8,    8  pci-pciexclass,060400          N/A                     /pci@0,600000/pci@0                                                                                 00  PCIe  0      bc, 8532, 10b5       3,  8,  0  okay     8,    8  pci-pciexclass,060400          N/A                     /pci@0,600000/pci@0/pci@8                                                                           00  PCIe  0      bc, 8532, 10b5       3,  9,  0  okay     1,    8  pci-pciexclass,060400          N/A                     /pci@0,600000/pci@0/pci@9                                                                           00  PCIx  0       8,  125, 1033       4,  0,  0  okay   100,  133  pci-pciexclass,060400          N/A                     /pci@0,600000/pci@0/pci@8/pci@0                                                                     00  PCIx  0       8,  125, 1033       4,  0,  1  okay    --,  133  pci-pciexclass,060400          N/A                     /pci@0,600000/pci@0/pci@8/pci@0,1                                                                   00  PCIx  0       2,   50, 1000       5,  1,  0  okay    --,  133  scsi-pci1000,50                LSI,1064                /pci@0,600000/pci@0/pci@8/pci@0/scsi@1                                                              00  PCIx  0      10, 1648, 14e4       5,  2,  0  okay    --,  133  network-pci14e4,1648           N/A                     /pci@0,600000/pci@0/pci@8/pci@0/network@2                                                           00  PCIx  0      10, 1648, 14e4       5,  2,  1  okay    --,  133  network-pci14e4,1648           N/A                     /pci@0,600000/pci@0/pci@8/pci@0/network@2,1                                                         00  PCIe  1       1, abcd, 108e       2,  0,  0  okay     8,    8  network-pciex108e,abcd         SUNW,pcie-qgc           /pci@1,700000/network@0                                                                             00  PCIe  1       1, abcd, 108e       2,  0,  1  okay     8,    8  network-pciex108e,abcd         SUNW,pcie-qgc           /pci@1,700000/network@0,1                                                                           00  PCIe  1       1, abcd, 108e       2,  0,  2  okay     8,    8  network-pciex108e,abcd         SUNW,pcie-qgc           /pci@1,700000/network@0,2                                                                           00  PCIe  1       1, abcd, 108e       2,  0,  3  okay     8,    8  network-pciex108e,abcd         SUNW,pcie-qgc           /pci@1,700000/network@0,3                                                                           00  PCIe  2       3, 2432, 1077       2,  0,  0  okay     4,    4  SUNW,qlc-pciex1077,2432        QLE2462                 /pci@2,600000/SUNW,qlc@0                                                                            00  PCIe  2       3, 2432, 1077       2,  0,  1  okay     4,    4  SUNW,qlc-pciex1077,2432        QLE2462                 /pci@2,600000/SUNW,qlc@0,1                                                                          00  PCIe  3       3, 2432, 1077       2,  0,  0  okay     4,    4  SUNW,qlc-pciex1077,2432        QLE2462                 /pci@3,700000/SUNW,qlc@0                                                                            00  PCIe  3       3, 2432, 1077       2,  0,  1  okay     4,    4  SUNW,qlc-pciex1077,2432        QLE2462                 /pci@3,700000/SUNW,qlc@0,1                                                                          ==================== Hardware Revisions ====================System PROM revisions:----------------------OBP 4.33.5.a 2012/01/13 15:05=================== Environmental Status ===================Mode switch is in LOCK mode =================== System Processor Mode ===================


3、fmadm; 查看输出,正常情况下是无输出的;

bash-3.2# fmadm faulty--------------- ------------------------------------  -------------- ---------TIME            EVENT-ID                              MSG-ID         SEVERITY--------------- ------------------------------------  -------------- ---------Jul 22 18:51:46 ecf24522-5df2-ef85-8ead-a0af51b30d08  SUN4U-8000-2S  Major     Host        : sunm4k_2Platform    : SUNW,SPARC-Enterprise     Chassis_id  : BDF1115195Product_sn  : Fault class : fault.memory.dimm 95%Affects     : mem:///unum=/MBU_A/MEMB3/MEM2A                  faulted but still in serviceFRU         : mem:///unum=/MBU_A/MEMB3/MEM2A 95%                  faultySerial ID.  : 522A45BE:M3 93T5660QZA-CE6 Description : The number of correctable errors associated with this memory              module has exceeded acceptable levels.Response    : Pages of memory associated with this memory module have been              removed from service, up to a limit which has now been reached.Impact      : Total system memory capacity has been reduced.Action      : Use 'fmadm faulty' to provide a more detailed view of this event.              Please refer to the associated reference document at              http://sun.com/msg/SUN4U-8000-2S for the latest service              procedures and policies regarding this diagnosis.



0